Skip to content
GATE TO THE WORLD · ENGINEERING SOFTWARE FOR HVAC MANUFACTURERS

Home / Software

Software for HVAC products. Ready-made or built for you.

Start with one of our proven package programs, or let us develop a new tool for your products and processes. Either way it runs in the cloud, in your brand.

An engineer selecting a swirl diffuser in the G2W Engineering Suite

G2W ENGINEERING SUITE

From selection to project.

One workspace for finding products, calculating and managing projects — in your brand, in your customers' language.

OPTION 1

Ready-made packages

  • Proven programs, already in use
  • Loaded with your products, data and brand
  • Short time to launch
  • Updated continuously

OPTION 2

Custom development

  • New tools for any HVAC product
  • Built around your engineering rules
  • Integrated with your ERP, CRM and website
  • Developed and maintained by engineers
More about custom software →

On every screen your customers use.

Cloud-based and runs on Windows, macOS and iOS — on the desktop in the design office, on a tablet on site, on a phone in the meeting.

G2W ENGINEERING SUITE EN ▾ · PROJECT: OFFICE L02
Air distribution
Silencers
Fans
Dampers
Thermal comfort
AHU coils
↓ Report · Drawing · BIM
occupied zone 1.8 m THROW 3.2 m · v < 0.25 m/sLwA 32 dB(A)
AIRFLOW
200 m³/h
Δp
7.0 Pa
LwA
29 dB(A)
STATUS
Selected
G2W · AHU COIL
FILTERHEAT REC.COOLING COILFANSILENCER COIL · 10 000 m³/hin 28 °C / 50 % → out 14 °C / 95 %Q 62.4 kW · water 7/12 °C · 2.98 l/s6 rows · 2.1 mm fins · Δp air 118 Pa coil selection report ↓
G2W · FAN
DUTY POINT3 600 m³/h · 420 Pasystemn 100%n 80% Pam³/h η 74 % · P 0.62 kW · SFP 0.6
Duty3 600 m³/h
Pressure420 Pa
Efficiency74 %
G2W
Swirl diffuser 400
SELECTED ✓
Q 200 m³/h
Δp 7.0 Pa
LwA 29 dB(A)
PDF report ↓

Inside the tools.

Real selection screens: enter the duty, compare results, download the report.

tools.[yourbrand].com/air-terminals LIVE DEMO
WATCH LIVE
0:30 · REAL SELECTION · LOOP

Air terminal selection. A complete selection in 30 seconds: room and duty in, the recommended diffuser out, then the airflow in section, plan and 3D.

Live screens · example project

TRY IT YOURSELF · LIVE DEMO

Try our software yourself.

A working demo, not a video: enter a room, press play and watch the air. Your customers can do the same on your website — with your diffusers and your data.

TRY ITG2W · ROOM AIRFLOW SIMULATOR

Ceiling diffusers in your room

THROW L0.22.4 m
SPACING4.00 m
MODECooling 9.0 K
TOTAL AIRFLOW880 m³/h

Good layout. Throw matches the spacing; air stays at the ceiling and reaches the occupied zone gently.

CHANGE ANY VALUE · PRESS ▶ · DRAG TO ROTATE
AIR VELOCITY m/s
0.10.250.5>1

Illustrative simulation · selection engine runs on your test data

AHU & COIL CALCULATOR · TRY IT

The whole unit in one view.

Change the airflow, open the exploded view and hover a section — filters, heat recovery, coils and fans with the unit data and documents beside them.

G2WAHU SELECTOR
PROJECT · OFFICE BUILDING L02 · AHU-01
SUPPLY → ← EXHAUST

Hover a section · example unit

Unit
[Your brand] AHU 16/22 · Indoor
Supply
10,000 m³/h · 400 Pa ext. · 2.0 m/s
Exhaust
10,000 m³/h · 400 Pa ext. · 2.0 m/s
Heat recovery
82.0 kW · 74.1 %
Supply filter
ePM1 60 % (F7)
Exhaust filter
ePM10 55 % (M5)
Cooling coil
46.2 kW · 7/12 °C
Heating coil
17.6 kW · 60/40 °C
Supply fan
EC · 3.4 kW
Exhaust fan
EC · 3.1 kW
Eurovent
Energy efficiency class A+ (example)
ErP
Ecodesign 2018 compliant
Size W×H×L
1.60 × 2.20 × 4.70 m
Price
From your price list

Our programs

Every program delivers calculation reports, product drawings and technical datasheets, and runs on Windows, macOS and iOS. Click a program to see what is inside.

G2W
Gr
Grille Selector
occupied zone 1.8 m THROW 3.2 m · v < 0.25 m/sLwA 32 dB(A)
2026
Engineering Suite
SELECTION · SIMULATION
Gr
G2W · Grille Selector
AIR DISTRIBUTION · SELECTION · SIMULATION

Grille selection

Supply, return and transfer grilles sized and checked in the room.

See what is inside →
G2W
Df
Diffuser Selector
occupied zone 1.8 m THROW 3.2 m · v < 0.25 m/sLwA 32 dB(A)
2026
Engineering Suite
SELECTION · SIMULATION
Df
G2W · Diffuser Selector
AIR DISTRIBUTION · SELECTION · SIMULATION

Diffuser selection & simulation

Select air terminals and see throw, velocity and comfort in the room.

See what is inside →
G2W
Si
Silencer Selector
SILENCER 1200 mm · 3 baffles 632501k8k Hz ATTENUATION dB Δp 18 Pa · NR 30 in the room
2026
Engineering Suite
SELECTION
Si
G2W · Silencer Selector
ACOUSTICS · SELECTION

Silencer selection

Attenuation and pressure drop for the right silencer size.

See what is inside →
G2W
Sc
Sound Calculator
fan Lwroom LpNR 35 limit 632501k8k fan → duct → silencer → terminal → room
2026
Engineering Suite
CALCULATION
Sc
G2W · Sound Calculator
ACOUSTICS · CALCULATION

System sound calculator

Sound from fan to room through ducts, silencers and terminals.

See what is inside →
G2W
Fn
Fan Selector
DUTY POINT3 600 m³/h · 420 Pasystemn 100%n 80% Pam³/h η 74 % · P 0.62 kW · SFP 0.6
2026
Engineering Suite
SELECTION
Fn
G2W · Fan Selector
FANS · SELECTION

Fan selection

Duty point, efficiency and sound for every fan in the range.

See what is inside →
G2W
Ah
AHU Calculator
FILTERHEAT REC.COOLING COILFANSILENCER COIL · 10 000 m³/hin 28 °C / 50 % → out 14 °C / 95 %Q 62.4 kW · water 7/12 °C · 2.98 l/s6 rows · 2.1 mm fins · Δp air 118 Pa coil selection report ↓
2026
Engineering Suite
CALCULATION · SELECTION
Ah
G2W · AHU Calculator
AIR HANDLING · CALCULATION · SELECTION

AHU calculation & selection

Air handling units sized section by section, with the full data sheet.

See what is inside →
G2W
Co
Coil Calculator
FILTERHEAT REC.COOLING COILFANSILENCER COIL · 10 000 m³/hin 28 °C / 50 % → out 14 °C / 95 %Q 62.4 kW · water 7/12 °C · 2.98 l/s6 rows · 2.1 mm fins · Δp air 118 Pa coil selection report ↓
2026
Engineering Suite
CALCULATION
Co
G2W · Coil Calculator
HEAT EXCHANGERS · CALCULATION

Coil calculation

Heating, cooling and DX coils calculated to the fin and tube.

See what is inside →
G2W
Dd
Duct Designer
600×300 · 2 400 m³/hv 3.7 m/s · Δp 0.9 Pa/m400×250250×200
2026
Engineering Suite
DESIGN · SELECTION
Dd
G2W · Duct Designer
DUCTWORK · DESIGN · SELECTION

Duct design & selection

Size and lay out duct networks with matching components.

See what is inside →
G2W
Dm
Damper Selector
BLADE ANGLE 30° · 600×600 Δp Pam³/h0°30° Δp 46 Pa · leakage class 3
2026
Engineering Suite
CALCULATION · SELECTION
Dm
G2W · Damper Selector
DAMPERS · CALCULATION · SELECTION

Damper calculation & selection

Flow, pressure drop, sound and leakage for control and fire dampers.

See what is inside →
G2W
Fc
Convector Selector
FLOOR CONVECTORQ 1 250 W · 75/65/20 °CL 2000 · H 110 mmfan-assisted · 3 steps EN 16430 output data
2026
Engineering Suite
CALCULATION · SELECTION
Fc
G2W · Convector Selector
HEATING · CALCULATION · SELECTION

Floor convector selection

Heat output per length, fan step and water regime.

See what is inside →
G2W
Rd
Room Designer
6 000OFFICE 1 · 48 m²OFFICE 2 · 52 m²CORRIDORD1 · 200 m³/hD2 · 220 m³/h LEVEL 02 · SUPPLY · 1:100
2026
Engineering Suite
DESIGN
Rd
G2W · Room Designer
ROOM · DESIGN

Room design tool

A complete ventilation product range, designed together in one room.

See what is inside →
G2W
Ic
Climate Designer
26.1 °C23.4 °C21.8 °C PMV +0.3 · PPD 7 % · CO₂ 780 ppmoverheating 42 h/a · annual cooling 18 kWh/m²
2026
Engineering Suite
DESIGN · SIMULATION
Ic
G2W · Climate Designer
INDOOR CLIMATE · DESIGN · SIMULATION

Indoor climate design tool

Plan temperature, airflow and comfort for the whole space.

See what is inside →
G2W
Pc
Configurator
595595H 280 LOD 300 · .RVT · .IFC · .STEP
2026
Engineering Suite
DESIGN
Pc
G2W · Configurator
CONFIGURATORS · DESIGN

Product configurator

A valid product from customer requirements.

See what is inside →
G2W
Ct
Digital Catalogue
EN · TR · DE · FR · ESalways up to date
2026
Engineering Suite
CATALOGUE
Ct
G2W · Digital Catalogue
SALES · CATALOGUE

Digital catalogues

Interactive product catalogues, always current, in every language.

See what is inside →

What every program delivers

Calculation reports

Detailed, branded reports for your customers and end users.

Product drawings

Dimensioned drawings for the exact product and size.

Technical datasheets

Complete performance datasheets, produced automatically.

See it on your own products.

Request a demo Call us · +43 664 142 01 99 Let us call you Contact page

Let's talk about your products.

Choose what suits you best.

Service partners: 24/7 support, 365 days a year.

We use your details to respond to your request. Privacy · Email us

HVAC SELECTION SOFTWARE

G2W builds selection, calculation and configuration software for HVAC manufacturers — web tools and apps for Windows, macOS and iOS.

Grille selection software

Supply, return and transfer grilles · air terminal device selection · throw and velocity check.

Diffuser selection software

Swirl, slot, linear, plenum and jet-nozzle diffusers · airflow simulation · comfort check.

Silencer selection software

Duct silencers and sound attenuators · insertion loss per octave band · pressure drop.

Convector selection software

Floor and trench convectors · output per length and fan step · EN 442.

Damper selection software

Volume control, VAV/CAV, fire and smoke dampers · leakage class · actuators.

Fan selection software

Duty point on the fan curve · efficiency, SFP and sound · HRV units.

AHU calculation software

Air handling units sized section by section · psychrometrics · SFP · Eurovent performance.

Coil calculation software

Heating, cooling, DX and condenser coils · capacity and pressure drop · Eurovent performance.

Sound & duct calculation

System sound from fan to room · NR level · duct sizing and pressure drop.

Room & indoor climate design

All terminals in one room · airflow and comfort simulation · draught risk.

Configurators, catalogues & BIM

Product configurator · digital catalogue · Revit families and BIM objects.

Custom HVAC software development

Engineering software built for your products · web, Windows, macOS, iOS.

Questions engineers and manufacturers ask

What is HVAC selection software?

A program that picks the right product size for a duty — for example a grille, diffuser, silencer, damper, fan or convector — and checks it against airflow, pressure drop, sound and comfort limits. G2W builds these tools for HVAC manufacturers, branded as their own.

Which selection programs does G2W make?

Grille selection, diffuser selection and simulation, silencer selection, system sound calculation, fan selection, AHU calculation, coil calculation, duct design, damper selection, floor convector selection, room and indoor climate design, product configurators and digital catalogues.

How does a diffuser or grille selection program work?

You enter the room, the airflow and the temperatures. The program proposes type and size, calculates throw, induction, occupied-zone velocity, pressure drop and sound, and shows the airflow in section, plan and 3D.

How is a duct silencer selected?

From the duct size, the length available, the airflow and the sound target. The program calculates the required insertion loss per octave band and lists every attenuator that fits, with pressure drop and regenerated noise.

Do the tools run on Windows, macOS and iOS?

Yes. The tools run in the browser and as apps for Windows, macOS and iOS, with the same calculations and reports on every device.

Can you build software for our own product range?

Yes. Pick from our ready-made programs or describe your idea; we scope it and send a proposal. Add-ons include pricing, production data and Eurovent performance (ECC) documentation.